GC-2025
Energy-Saving Gas Chromatograph
Shimadzu's
new-generation GC-2025 capillary gas chromatograph minimizes environmental
impact by reducing power and carrier gas consumption while retaining the
performance capabilities required for capillary analysis.
The GC-2025
incorporates a digital flow controller that controls both the carrier and
detector gases and a newly designed energy-saving column oven that features
small volume and less heating loss, realizing a dramatic improvement in operation
costs.
The compact
GC-2025 is the gas chromatograph for environmentally friendly, high value
performance.
Eco-Friendly
The
eco-friendly GC-2025 significantly cuts electric power costs compared to
previous models to reduce the burden on the environment.
Heat losses are
significantly reduced through high-performance insulation and a smaller oven
size to reduce the heating requirements. In addition, it incorporates an
energy-saving heater to further cut power costs.
Power
consumption is reduced by 30% for programmed temperature analysis in comparison
to other GC models.
(The actual
power consumption depends on the ambient temperature during analysis.)
Comparison of Power Consumption Per Analysis Cycle |
In recent
years, there has been an increasing demand for instruments with a smaller
installation footprint to more effectively utilize laboratory space. The
GC-2025 meets this requirement while incorporating all the functions required
for normal capillary analysis.
Comparison of GC (Top View) |
Units for Normal Analysis Crowded into a
Compact Space
The
split/splitless injection unit (SPL), flame ionization detector (FID), and
electronic flow controllers (AFC/APC)
are installed as standard.
Compact Design Accepts Commercial Capillary
Columns Despite the
compact instrument design, the small-capacity oven accommodates the shape of
commercially available capillary columns (column depth 9 cm max.).
Excellent Basic Performance
Incorporating
design elements from the high-performance GC-2010 Plus capillary gas
chromatograph, the GC-2025 achieves energy savings while offering the highest
performance demanded for capillary analysis, delivering highly accurate
analysis results and enhanced productivity.
High-Sensitivity Trace Analysis
The FID minimum
detectable limit of 2 pgC/s offers high sensitivity for trace analysis.
Electronic Flow
Controllers Achieve Excellent Operability and Reproducibility
The GC-2025
adopts the same well-proven electronic flow controllers (AFC/APC) for carrier
gas and detector gas control that are used in the GC-2010 Plus. They offer
highly accurate flow control to achieve excellent reproducibility.
This product
conforms to Shimadzu's Eco-labeled designation.
* Energy
savings: 30% reduction as compared to the previous model
ĐẠI DIỆN ĐỘC QUYỀN SHIMADZU TẠI VIỆT NAM
Hotline: 0902 550 957
TRỤ SỞ TẠI TP. HỒ CHÍ MINH: 6A-6B Nguyễn Cảnh Chân, Quận 1, TP Hồ Chí Minh
VPĐD TẠI TP. HÀ NỘI: 12-14 Cửa Nam, Quận Hoàn Kiếm, TP. Hà Nội
Email: huynhthanhmt06@gmail.com
Website: shimadzu-vietnam.com