Eco-Friendly GC-2025


GC-2025
Energy-Saving Gas Chromatograph
Shimadzu's new-generation GC-2025 capillary gas chromatograph minimizes environmental impact by reducing power and carrier gas consumption while retaining the performance capabilities required for capillary analysis.
The GC-2025 incorporates a digital flow controller that controls both the carrier and detector gases and a newly designed energy-saving column oven that features small volume and less heating loss, realizing a dramatic improvement in operation costs.
The compact GC-2025 is the gas chromatograph for environmentally friendly, high value performance.
Gas Chromatograph GC-2025 
Eco-Friendly
The eco-friendly GC-2025 significantly cuts electric power costs compared to previous models to reduce the burden on the environment.
Heat losses are significantly reduced through high-performance insulation and a smaller oven size to reduce the heating requirements. In addition, it incorporates an energy-saving heater to further cut power costs.
Power consumption is reduced by 30% for programmed temperature analysis in comparison to other GC models.
(The actual power consumption depends on the ambient temperature during analysis.)
Comparison of Power Consumption
Comparison of Power Consumption Per Analysis Cycle
Compact, All-in-One Design
In recent years, there has been an increasing demand for instruments with a smaller installation footprint to more effectively utilize laboratory space. The GC-2025 meets this requirement while incorporating all the functions required for normal capillary analysis.
Comparison of GC (Top View)
Comparison of GC (Top View)
Units for Normal Analysis Crowded into a Compact Space
The split/splitless injection unit (SPL), flame ionization detector (FID), and electronic flow controllers  (AFC/APC) are installed as standard.

Compact Design Accepts Commercial Capillary Columns Despite the compact instrument design, the small-capacity oven accommodates the shape of commercially available capillary columns (column depth 9 cm max.).
Excellent Basic Performance
Incorporating design elements from the high-performance GC-2010 Plus capillary gas chromatograph, the GC-2025 achieves energy savings while offering the highest performance demanded for capillary analysis, delivering highly accurate analysis results and enhanced productivity.

High-Sensitivity Trace Analysis
The FID minimum detectable limit of 2 pgC/s offers high sensitivity for trace analysis.
Electronic Flow Controllers Achieve Excellent Operability and Reproducibility
The GC-2025 adopts the same well-proven electronic flow controllers (AFC/APC) for carrier gas and detector gas control that are used in the GC-2010 Plus. They offer highly accurate flow control to achieve excellent reproducibility.
This product conforms to Shimadzu's Eco-labeled designation.
* Energy savings: 30% reduction as compared to the previous model


ĐẠI DIỆN ĐỘC QUYỀN SHIMADZU TẠI VIỆT NAM
Hotline0902 550 957
TRỤ SỞ TẠI TP. HỒ CHÍ MINH: 6A-6B Nguyễn Cảnh Chân, Quận 1, TP Hồ Chí Minh
VPĐD TẠI TP. HÀ NỘI: 12-14 Cửa Nam, Quận Hoàn Kiếm, TP. Hà Nội
Email: huynhthanhmt06@gmail.com

Share this

Related Posts

Previous
Next Post »