Hiển thị các bài đăng có nhãn GC. Hiển thị tất cả bài đăng
Hiển thị các bài đăng có nhãn GC. Hiển thị tất cả bài đăng

Nexis GC-2030


Nexis GC-2030

Gas Chromatography

Nexis GC-2030, Shimadzu's premier gas chromatograph, offers a modern approach to a classic chromatographic technique. Designed with the user in mind, new innovative features, exceptional performance and high-throughput capabilities will elevate your lab to the next level.
Designed with the Analyst in Mind
Designed with the Analyst in Mind
Information at Your Finger-tips
Making Routine Analysis Convenient with ClickTek
Intuitive Graphical Icons and Mobile Device Monitoring

World's Highest* Sensitivity and Reproducibility
World's Highest* Sensitivity and Reproducibility
High-Sensitivity Detectors Support a Wide Variety of Analyses
Intelligent Flow Controller with Exceptional Reproducibility
* As of May 2017, according to a Shimadzu survey

Exceptional Extensibility and Productivity
Exceptional Extensibility and Productivity
GC Systems Customized for Specific Needs
Advanced Flow Technology
Faster Analysis with Hydrogen Carrier Gas

Various Advanced Functions Improve Energy Efficiency
Various Advanced Functions Improve Energy Efficiency
Maximized Column Oven Functionality
Minimized Running Costs
Minimized Helium Gas Consumption
Diagnoses Instrument Operating Status
Automatic Notification of Replacement Timing

Options for Expanding Your Productivity
Options for Expanding Your Productivity
Inlets
Detectors

Software Improves Laboratory Productivity
Software Improves Laboratory Productivity
Software Improves Laboratory Productivity
Application Systems Tailored to Your Analytical Requirements


ĐẠI DIỆN CHÍNH THỨC SHIMADZU TẠI VIỆT NAM
Hotline: 0902 550 957
VP TẠI TP. HỒ CHÍ MINH: 6A-6B Nguyễn Cảnh Chân, Quận 1, TP Hồ Chí Minh
VP TẠI TP. HÀ NỘI: 12-14 Cửa Nam, Quận Hoàn Kiếm, TP. Hà Nội
Email: huynhthanhmt06@gmail.com

GC-2010 Plus High-end GC

GC-2010 Plus High-end GC


Achieves Higher Sensitivity and Improves Productivity

Gas Chromatograph GC-2010 Plus
The GC-2010 Plus enables reliable, high-precision trace analysis with high repeatability, utilizing detectors such as FID and FPD that feature best-in-class sensitivity.
In addition, rapid oven cooling and backflush technology shorten analysis time greatly for significant improvements in productivity.
 Gas Chromatograph GC-2010 Plus
Features

Trace Amount Analysis

Detector Lineup 2010 Plus Series

A lineup of powerful detectors ensures the highest sensitiivty - even for trace amount analysis.

Functions to improve analytical efficiency and productivity
Rapid oven cooling, backflushing technology, gas saver function, etc.

Advanced Flow Technology
New flow-controlling technologies enable higher separation capability and faster analysis.

Broad Lineup of Units
You can select the most suitable detector and injection unit for your sample. Retrofitting of these units is easy.
Detectors
Injectors
・FID-2010 Plus
 Flame ionization detector
・SPL-2010 Plus
 Split/splitless injection unit
・TCD-2010 Plus
 Thermal Conductivity Detector
・WBI-2010 Plus
 Direct Injection Unit
・FPD-2010 Plus
 Flame Photometric Detector
・OCI/PTV-2010
 On-column/ programmed temperature injection unit
・ECD-2010 Exceed
・ECD-2010 Plus
 Electron Capture Detector

・FTD-2010 Plus
 Flame Thermionic Detector



ĐẠI DIỆN ĐỘC QUYỀN SHIMADZU TẠI VIỆT NAM
Hotline: 0902 550 957
TRỤ SỞ TẠI TP. HỒ CHÍ MINH: 6A-6B Nguyễn Cảnh Chân, Quận 1, TP Hồ Chí Minh
VPĐD TẠI TP. HÀ NỘI: 12-14 Cửa Nam, Quận Hoàn Kiếm, TP. Hà Nội
Email: huynhthanhmt06@gmail.com


GC-2014 Standard Capillary and Packed Gas Chromatograph

GC-2014 Standard Capillary and Packed Gas Chromatograph


Versatile standard Capillary and Packed Gas Chromatograph
Get the high performance of the GC-2010 now also for your routine work. Based on the successful design of the GC-2010, the GC-2014 gives best results for routine analysis for a good price-performance ratio. Whether you work with packed or capillary columns, the GC-2014 provides excellent performance.
 GC-2014
Performance lifted to a higher level
The GC-2014 Series is equipped with the advanced flow controller (AFC) technology inherited from the GC-17A Series and GC-2010 Series. This digital control is standard for not only capillary columns, but packed columns as well. Accurate flow rate control via AFC has higher-level repeatability of retention time and peak area, enabling a higher level of analyses.

The detectors have been completely redesigned, incorporating the GC-2010 detector designs for capillary analyses and the GC-14 detector designs for packed columns. This TCD-2014 unit is ideal for packed column measurements employing the semi-diffusion cell design used in TCD-14. The newly designed FPD-2014 takes advantage of the holophotal construction of the FPD-2010.

Easier to understand, simpler operation
A large LCD displays chromatograms and method parameters. Graphical popup screen that clearly guides operation so that operation errors are prevented. The built-in Help function almost eliminates need for familiarization training.
Self-diagnostics validate that the instrument before injection. Regular diagnosis prevents unexpected downtime.

Expandability to Support all Types of Analysis
GC-2014
Column replacement is easier in large column oven
Select from four types of injection units and five types of detectors according to the target compounds and analysis objective. Modular injection units, detectors and auto-injectors can be easily added after installing the unit in your lab. Three Injection Units and Four Detectors can be simultaneously installed.
Effective use of valuable column resources is maintained by using the 40-mm pitch glass column the same as Shimadzu GC-7, 9, 12, 14, 15 and 16 Series.

A Full Line of Injection Units and Compact, High-Sensitivity Detectors

Injection Units DINJ-2014
Dual Packed Injection Unit
Designed for Dual FID and TCD analyses. Because two flow paths are handled
using one temperature control port, these count as one heated zone.
SPL-2014 Split/Splitless Injection Unit
Standard unit for high-speed analysis with a narrow bore column. The gas saver function restricts the total gas used. High-pressure injection standard
SINJ-2014 Single Packed Injection Unit
This is a specialized sample injection unit for use with ECD or other high sensitivity detectors.
WBI-2014 Direct Injection Unit
Incorporates a septum purge flow path to restrict solvent tailing. Sharing glass inserts with splitless analysis simplifies parts requirements (patented).

Detectors

FID-2014
Flame Ionization Detector
Automatic ignition and re-ignition functions are standard. By mounting an APC or solenoid valve unit, a feedback function cuts off gas supply when the hydrogen flame is extinguished. Generally used for detection of organic compounds with a hydrogen carbon bond. Single and dual FID's arele. availa
  
TCD-2014
Thermal Conductivity Detector
The TCD-2014 is a semi-diffusion type cell reducing contamination and increasing cell lifetimes. Incorporates an automatic filament protection circuit. The TCD-2014 is used for analysis of inorganic gases and concentrated organic compounds.


ECD-2014
Electron Capture Detector
This cell is very similar to the ECD-14; so spare radiation sources can be shared. This detector is used for analysis of electrophillic compounds. Improved cell insulation and reduces contamination achieving higher sensitivity.


FPD-2014
Flame Photometric Detector
The FPD-2010, the nozzle system was updated to provide support for packed column analysis while maintaining its high sensitivity. The FPD-2014 is compact with a high maximum temperature (350deg.C). This detector is used for analysis of organic sulphur compounds and organic phosphorus compounds such as residual pesticides and malodorous components.

FTD-2014
Flame Thermionic Detector
Packed column analysis is supported by the FTD-2014 using the FTD-14 mechanism and collectors from both the FTD-14 and -17. Used for analysis of organic nitrogen compounds and organic phosphorus compounds such as residual pesticides.


FTD-2014C
Flame Thermionic Detector
This specialized capillary-type detector employs the FTD-2010 mechanism. Used for analysis of organic nitrogen compounds and organic phosphorus compounds such as residual pesticides. The new collector construction allows replacement without tools. An optional alkali source regeneration kit recoats the bead reducing running costs.

ĐẠI DIỆN ĐỘC QUYỀN SHIMADZU TẠI VIỆT NAM
Hotline: 0902 550 957
TRỤ SỞ TẠI TP. HỒ CHÍ MINH: 6A-6B Nguyễn Cảnh Chân, Quận 1, TP Hồ Chí Minh
VPĐD TẠI TP. HÀ NỘI: 12-14 Cửa Nam, Quận Hoàn Kiếm, TP. Hà Nội
Email: huynhthanhmt06@gmail.com

Eco-Friendly GC-2025

Eco-Friendly GC-2025


GC-2025
Energy-Saving Gas Chromatograph
Shimadzu's new-generation GC-2025 capillary gas chromatograph minimizes environmental impact by reducing power and carrier gas consumption while retaining the performance capabilities required for capillary analysis.
The GC-2025 incorporates a digital flow controller that controls both the carrier and detector gases and a newly designed energy-saving column oven that features small volume and less heating loss, realizing a dramatic improvement in operation costs.
The compact GC-2025 is the gas chromatograph for environmentally friendly, high value performance.
Gas Chromatograph GC-2025 
Eco-Friendly
The eco-friendly GC-2025 significantly cuts electric power costs compared to previous models to reduce the burden on the environment.
Heat losses are significantly reduced through high-performance insulation and a smaller oven size to reduce the heating requirements. In addition, it incorporates an energy-saving heater to further cut power costs.
Power consumption is reduced by 30% for programmed temperature analysis in comparison to other GC models.
(The actual power consumption depends on the ambient temperature during analysis.)
Comparison of Power Consumption
Comparison of Power Consumption Per Analysis Cycle
Compact, All-in-One Design
In recent years, there has been an increasing demand for instruments with a smaller installation footprint to more effectively utilize laboratory space. The GC-2025 meets this requirement while incorporating all the functions required for normal capillary analysis.
Comparison of GC (Top View)
Comparison of GC (Top View)
Units for Normal Analysis Crowded into a Compact Space
The split/splitless injection unit (SPL), flame ionization detector (FID), and electronic flow controllers  (AFC/APC) are installed as standard.

Compact Design Accepts Commercial Capillary Columns Despite the compact instrument design, the small-capacity oven accommodates the shape of commercially available capillary columns (column depth 9 cm max.).
Excellent Basic Performance
Incorporating design elements from the high-performance GC-2010 Plus capillary gas chromatograph, the GC-2025 achieves energy savings while offering the highest performance demanded for capillary analysis, delivering highly accurate analysis results and enhanced productivity.

High-Sensitivity Trace Analysis
The FID minimum detectable limit of 2 pgC/s offers high sensitivity for trace analysis.
Electronic Flow Controllers Achieve Excellent Operability and Reproducibility
The GC-2025 adopts the same well-proven electronic flow controllers (AFC/APC) for carrier gas and detector gas control that are used in the GC-2010 Plus. They offer highly accurate flow control to achieve excellent reproducibility.
This product conforms to Shimadzu's Eco-labeled designation.
* Energy savings: 30% reduction as compared to the previous model


ĐẠI DIỆN ĐỘC QUYỀN SHIMADZU TẠI VIỆT NAM
Hotline: 0902 550 957
TRỤ SỞ TẠI TP. HỒ CHÍ MINH: 6A-6B Nguyễn Cảnh Chân, Quận 1, TP Hồ Chí Minh
VPĐD TẠI TP. HÀ NỘI: 12-14 Cửa Nam, Quận Hoàn Kiếm, TP. Hà Nội
Email: huynhthanhmt06@gmail.com

GC-8A Basic GC

Basic Gas Chromatograph Model

Simple, Dedicated, Single Detector Gas Chromatographs



The reliable and compact GC-8A is Shimadzu's basic gas chromatograph model for dedicated applications. Economical and simple to use, the GC-8A supports a single detector, manual pressure or flow control, on column injection port(s), and analog output. Isothermal or single temperature ramp program models are available. The GC-8A is only 17.3 inches (43.9 cm) wide, yet its large oven facilitates simple column installation and maintenance. Detectors available:

-        FID (Flame Ionization Detector)
-        TCD (Thermal Conductivity Detector)
-        ECD (Electron Capture Detector
-        FPD (Flame Photometric Detector)

GC-8A Specifications

Models available
Isothermal with TCD

Temperature program with TCD

Isothermal with FID

Temperature program with FID

Isothermal with ECD

Temperature program with FPD
Column oven temperature
(isothermal models)
Temperature range:Ambient to 399oC (1oC increments)

Temperature control:Proportional integration type

Temperature control accuracy: ± 0.1oC

Heating speed:Ambient to 350oC in 13 minutes

Cooling speed: 350oC to 100oC in 3.5 minutes
Column oven temperature
(temperature program models)
Temperature range: -100oC to 400oC (cryogenic accessories required for sub-ambient temp. operation)

Temperature control:Proportional integration type

Temperature control accuracy: ± 0.1oC

Heating speed: Ambient to 350oC in 13 minutes

Cooling speed:350oC to 100oC in 3.5 minutes
Temperature program
(temperature program models)
Initial temperature: -100oC to 399oC (1oC increments)

Final temperature: 0oC to 400oC (10o increments)

Program rate:0.5,1,2,3,4,5,6,8,10,16,20,32oC/min
Overheat protection
Two stage protection:
If the temp. exceeds the set temp. by 30oC,the heater is automatically turned off
If the temperature exceeds 420oC, the heater is automatically turned off
Injection port/detector temperature
Temperature range:Ambient to 400oC (10o increments)

Ambient to 350oC (ECD model)

Temperature control:Proportional integration type

Temperature control accuracy: ± 0.1oC

Overheat protection:yes
Temperature control
(isothermal models)
The column oven, injection port/detector, auxiliary temperatures are selectively indicated; when temperatures have reached the set point, READY is indicated.
Temperature control
(temperature program models)
The column oven, injection port/detector, auxiliary temperatures are selectively indicated, with pushbutton selection
Columns
Stainless steel:6 m x 2

Stainless steel (FPD, ECD models):12 m x 1 Glass:5.4 m x 2

Glass (FPD, ECD models):5.4 m x 1

Capillary (with option):100 m x 1

Capillary (ECD model, with option):100 m x 1
Injection port
Two on-column injection ports

FPD, ECD models:One on-column injection port
Flow control: carrier gas
(isothermal models)
TCD, FID models:Two pressure regulators and two column inlet pressure gauges.
Flow control: carrier gas
(isothermal models)
ECD model:One pressure regulator and one column inlet pressure gauge
Flow control: carrier gas
(temperature program models)
TCD, FID models:One primary pressure indicator, one primary pressure gauge, two differential flow controllers, and two column inlet pressure gauges
Flow control: carrier gas
(temperature program models)
FPD model:One primary pressure regulator, one primary pressure gauge, one differential flow controller, and one column inlet pressure gauge
Flow control: Hydrogen
FID models:Two pressure regulators and two column inlet pressure gauges
Flow control: Air
FID models:One pressure regulator and one pressure gauge
Dimensions (mm) and Weight
(kg) (isothermal models)
TCD model:440W x 405D x 435H, 26.5

FID model:440W x 405D x 570H, 34.5

ECD model:440W x 405D x 435H, 26.0
Dimensions (mm) and Weight
(kg) (temperature program models)
TCD model:440W x 405D x 625H, 36.0

FID model:440W x 405D x 625H, 34.5

FPD model:440W x 405D x 785H, 35.0
Power requirements
AC 100/115V or 200/220V as ordered, 1500VA max., 50/60 Hz



ĐẠI DIỆN ĐỘC QUYỀN SHIMADZU TẠI VIỆT NAM
Hotline: 0902 550 957
TRỤ SỞ TẠI TP. HỒ CHÍ MINH: 6A-6B Nguyễn Cảnh Chân, Quận 1, TP Hồ Chí Minh
VPĐD TẠI TP. HÀ NỘI: 12-14 Cửa Nam, Quận Hoàn Kiếm, TP. Hà Nội
Email: huynhthanhmt06@gmail.com